MKS base 1.5 (E0 & E1) not working
I have bought two MKS base 1.5 boards. Both extruder ports are not working. I made sure the stepper motor still works and that there is nothing wrong with the Marlin firmware that I know of.
Any ideas?
I figured out what was wrong. Turns out the no extrude command was uncommented and worked fine when changed the min temp on it.
Are the E0 and the E1 ports not working on *both* of the boards that you purchased?
@Chris Manning - I see that you commented on the deleted answer from pisstoff (that was converted to a comment) the following: `I figured out what was wrong. Turns out the no extrude command was uncommented and worked fine when changed the min temp on it.` Could you post that comment as an answer and mark the answer as accepted? That would remove your question from the unanswered list, and as a beta site we need to keep that list short. Thanks in advance.
The OP has solved the problem as read from a comment on a deleted answer. So far the OP has been reluctant to post the answer; therefore his comment is converted into a community answer.
It appears that the OP had incorrectly configured his firmware considering the comment:
"I figured out what was wrong. Turns out the no extrude command was uncommented and worked fine when changed the min temp on it."
License under CC-BY-SA with attribution
Content dated before 7/24/2021 11:53 AM
pisstoff 6 years ago
Is the hotend above 170 °C? Because Marlin will not turn on `E0` and `E1` until it can extrude without causing damage.