Can I use 20 gauge wire for my Mk2a Heatbed?
I purchased the following wire for my MK2a heated bed:
McMaster Carr
1 8209K11 840 Degree F Braided Oven Wire 20 Gauge, Tan, 10 ft. Length 1Will this be acceptable? I'd like to print with ABS, which I know that the heatbed has to be hotter than when printing with PLA.
@tbm0115 please wait...I'm still learning more anout power on a question on another SE site: http://diy.stackexchange.com/questions/93374/where-can-i-find-the-trip-curve-for-this-circuit-breaker
Your wire should be rated for at least the necessary 11 amps which the MK2a heatbed is supposed to take.
You can check this by measuring the resistivity of your wire:
Always test the heatbed wiring for resistance. Remember, at 10A, 0.1Ohms means 1V voltage drop means 10W dissipated by the wiring!
as taken from http://forums.reprap.org/read.php?392,493405 (useful read for seeing what CAN actually happen)
Did you read through the following links? They might clear up some questions:
http://reprap.org/wiki/PCB_Heatbed
http://reprap.org/wiki/Heatbeds_-_A_beginner's_guideI personally would use 1.5 mm² cables, which translates to about 15 gauge wire.
*edit: This is a nice table to check:
http://www.powerstream.com/Wire_Size.htmIs a higher wire gauge a thicker wire gauge? (here: http://forums.reprap.org/read.php?392,493405)
lower wire gauge number means thicker wire. Here you can translate it to metric units: http://www.rapidtables.com/calc/wire/awg-to-mm.htm
If you're in the US, 14AWG is commonly available and will suffice for a continuous load of 11A. 14AWG is rated (by building code, not necessarily relevant here) to 15A intermittently or 12A continuously.